086 DTSY1352 Three-Phase Electronic Prepayment Energy Meter Installation and User Manual

This document is the installation and user manual for the 086 DTSY1352 three-phase electronic prepayment energy meter produced by Ankora Electric Co., Ltd. The energy meter has functions such as prepaid electricity, load control, and RS485 communication. It is used to measure the active energy of three-phase AC with a rated frequency of 50Hz. The performance of the energy meter complies with the GB/T18460.3-2001 standard and is an ideal energy meter for reforming the traditional power consumption system and improving power consumption management.


086 DTSY1352 Three-Phase Electronic Prepayment Energy Meter Installation and User Manual - cover page
Brand
Acrel
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
872 KB
Published
26 September, 2022
Updated
28 September, 2023
MD5 checksum
82058736495BE6AD0B48CBE0457CAC83

About this manual

The Acrel DTSY1352 is a three-phase electronic prepaid energy meter designed for measuring active energy in AC systems with a rated frequency of 50Hz. It features prepaid functionality using logic encrypted IC cards, load control capabilities, and optional RS485 communication. The device complies with GB/T18460.3-2001 standards and is intended to improve electricity management levels.

The manual details the meter's technical parameters, including voltage inputs of 3×220/380V or 3×380V, and current inputs ranging from 1.5(6)A to 20(80)A. It provides instructions for various wiring configurations, such as direct access and transformer access, and explains the operation of the LCD display, IC card insertion, and prepaid control logic. Additionally, it outlines the MODBUS-RTU communication protocol and register addresses for data retrieval and configuration. This manual is written in Chinese.

What's inside

  • Overview
  • Main Functions
  • Technical Parameters
  • Dimensions
  • Wiring and Installation
  • Usage and Operation
  • Communication Description

Specifications

Rated Voltage3×220/380V, 3×380V AC
Reference Frequency50Hz
Power Consumption<2VA (per phase)
Input Current1.5(6)A, 5(20)A, 10(40)A, 20(80)A
Measurement AccuracyClass 1
Measurement Range0000 00.00~99999999 kWh
Pulse Constant6400, 1600, 800, 400 imp/kWh
Communication ProtocolMODBUS-RTU
Dimensions144mm×85mm×74mm
Operating Temperature-20℃~60℃

Frequently asked questions

What is the rated voltage of the DTSY1352?

The rated voltage is 3×220/380V or 3×380V AC.

Does the meter support RS485 communication?

Yes, it supports RS485 interface with the MODBUS-RTU protocol.

How does the prepaid function work?

It uses logic encrypted IC cards to implement a pay-first-then-use management function.

What is the measurement accuracy class?

The measurement accuracy is Class 1.

Download PDF (872 KB)

More Acrel Manuals


View all Acrel manuals →