This manual is the user quick reference manual for the IVC2L series PLC, introducing the features and usage of the product.
This document serves as a quick reference manual for the Inovance IVC2L series Programmable Logic Controller (PLC) main module. It is designed to assist users in the design, installation, connection, and maintenance of the product by providing rapid access to essential information. The manual includes details on hardware specifications, features, usage methods, and a list of optional accessories. This manual is written in Chinese.
| Input Voltage Range | 85-264 Vac |
|---|---|
| Rated Output Current (5V/GND) | 1000 mA |
| Rated Output Current (24V/GND) | 650 mA |
| Maximum Output Power | 35W |
| High Speed Input Frequency (X0, X1) | 50kHz |
| High Speed Input Frequency (X2-X5) | 10kHz |
| Relay Output Max Current (Resistive) | 2A/1 point |
| Transistor Output Max Current (Resistive) | 0.3A/1 point |
The COM terminal is the common ground for both the +24Vdc auxiliary power supply and input signals.
Relay outputs are dry contacts suitable for high voltage/current loads, while transistor outputs are for high-frequency applications like servos.