UniStrong E640 User Manual

E640 is a new generation high-precision static measurement system developed by Hezhong Sizhuang. It features an integrated design that combines GPS antenna, GPS receiver, lithium battery, and data storage. The system has excellent performance in tracking multiple GPS satellites, and it is waterproof, dustproof, and shockproof. It is easy to operate and has a large storage capacity. It can be widely used in control measurement, engineering measurement, GIS data collection, cadastral survey, and area measurement.


UniStrong E640 User Manual - cover page
Brand
Beijing合众思壮
Category
Other device
Document type
User Manual
Language
Chinese
Pages
28
File format
PDF
File size
916 KB
Published
19 September, 2011
Updated
29 September, 2023
MD5 checksum
81E6E397773CBE7A6F63682A15BD7D55

About this manual

The UniStrong E640 is a high‑precision static measurement system that integrates a GPS antenna, receiver, lithium‑battery and flash storage in a sealed, waterproof, dust‑proof and shock‑proof housing. It is designed for control surveying, engineering surveying, GIS data collection and boundary measurement.

The manual is organized into chapters covering product overview, panel operation, device setup, field data processing, engineering case studies and safety precautions, with detailed descriptions of interfaces, power options, button functions, accuracy specifications and data management procedures. This manual is written in Chinese.

What's inside

  • Overview
  • Panel Operation Details
  • Device Usage
  • Engineering Cases
  • Field Data Processing and Verification
  • Precautions

Specifications

Power consumption (idle)<0.6 W
Battery capacity4200 mAh
Operating time (battery)>30 h
Charging time<5 h
Horizontal accuracy (static)±5 mm + 1 ppm
Elevation accuracy (static)±10 mm + 1 ppm
Dimensions (L×W×H)161 × 152 × 106 mm
Operating temperature range-30 °C to 70 °C
Ingress protectionIPX67

Frequently asked questions

What power sources can the E640 use?

The E640 can be powered either by its internal lithium‑battery or by an external 12 V DC supply, with automatic switching between them.

How long does the internal battery last on a full charge?

A fully charged internal battery allows the E640 to operate continuously for more than 30 hours.

What is the measurement accuracy of the E640?

In static mode the system provides horizontal accuracy of ±5 mm + 1 ppm and elevation accuracy of ±10 mm + 1 ppm.

Download PDF (916 KB)