Motorola MCR506 Series SCR Thyristor Datasheet

MCR506 is a thyristor device produced by Motorola. The device has high reliability and uniformity, economical power rating, practical level triggering and holding characteristics, flat, rugged, thermopad construction for low thermal resistance, high heat dissipation and durability.


Motorola MCR506 Series SCR Thyristor Datasheet - cover page
Brand
Motorola
Category
SCR
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
89 KB
Published
09 August, 2012
Updated
30 September, 2023
MD5 checksum
9EEF60F9CDB1FF767DA4ACD8D1F8699C

About this manual

The Motorola MCR506 Series datasheet describes 6 A RMS SCR thyristors in the MCR506-2, MCR506-3, MCR506-4, MCR506-6, and MCR506-8 voltage variants. It lists blocking-voltage ratings of 50, 100, 200, 400, and 600 V and identifies the devices as designed for high-volume consumer applications such as temperature, light, and speed control, process and remote control, and warning systems.

The datasheet provides maximum ratings, thermal characteristics, and electrical characteristics, plus current-derating and power-dissipation figures. It also gives Case 77-08 (TO-225AA) package dimensions and Style 2 pin assignments: pin 1 cathode, pin 2 anode, and pin 3 gate.

What's inside

  • Maximum Ratings
  • Thermal Characteristics
  • Electrical Characteristics
  • Current Derating
  • Power Dissipation
  • Package Dimensions
  • Case 77-08 (TO-225AA) Pinout

Specifications

Blocking Voltage Ratings (MCR506-2/-3/-4/-6/-8)50, 100, 200, 400, 600 V
RMS Forward Current6 A
Average Forward Current3.82 A at TC = 93°C
Peak Non-repetitive Surge Current40 A
Operating Junction Temperature Range–40 to 110 °C
Storage Temperature Range–40 to 150 °C
Thermal Resistance, Junction to Case3 °C/W
Thermal Resistance, Junction to Ambient75 °C/W
Forward On Voltage1.9 V
PackageCase 77-08 (TO-225AA), Style 2

Frequently asked questions

What is the RMS forward current of the Motorola MCR506 Series?

The RMS forward current is 6 A for all conduction angles.

What voltage ratings are available in the MCR506 Series?

The series includes 50, 100, 200, 400, and 600 V blocking-voltage ratings.

What package does the MCR506 Series use?

It uses Case 77-08 (TO-225AA), Style 2, with cathode, anode, and gate pins.

What is the operating junction temperature range?

The operating junction temperature range is –40 to 110 °C.