MACOM A78/SMA78 Cascadable Amplifier Datasheet

This document describes the specifications and performance characteristics of a cascaded amplifier called A78/SMA78, which operates in the 5-300 MHz frequency range. The amplifier features high dynamic range, high output, high third order intercept point, and low noise figure.


MACOM A78/SMA78 Cascadable Amplifier Datasheet - cover page
Brand
MACOM
Category
amplifier
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
112 KB
Published
09 August, 2012
Updated
28 September, 2023
MD5 checksum
5808864668E5491E4E29BFD55D106770

About this manual

This document provides technical specifications for the MACOM A78 and SMA78 cascadable amplifiers, which operate in the 5 to 300 MHz frequency range. Key performance metrics include a typical high output of +19.0 dBm, a low noise figure of 3.5 dB, and a high third-order intercept point of +35 dBm.

The datasheet details absolute maximum ratings, such as a maximum DC voltage of +17 Volts and a maximum case temperature of 125°C. It also includes thermal data, specifying a thermal resistance of 75°C/W, and outlines the available package types, including TO-8 Surface Mount and SMA Connectorized versions.

What's inside

  • Specifications
  • Absolute Maximum Ratings
  • Thermal Data
  • Package Types
  • Frequency Range
  • Gain
  • Noise Figure
  • Power Output

Specifications

Frequency Range5 to 300 MHz
High Dynamic Range+114 dB/1 MHz
Typical Output Power+19.0 dBm
Typical Third Order Intercept+35 dBm
Typical Noise Figure3.5 dB
Maximum DC Voltage+17 Volts
Maximum Case Temperature125°C
Thermal Resistance75°C/W

Frequently asked questions

What is the frequency range of the A78/SMA78 amplifier?

The amplifier operates in the 5 to 300 MHz frequency range.

What are the available package types?

The device is available in TO-8 Surface Mount and SMA Connectorized packages.

What is the maximum DC voltage rating?

The maximum DC voltage rating is +17 Volts.

Download PDF (112 KB)