STMicroelectronics STPMC1 Programmable Poly-phase Energy Calculator IC Datasheet

This product is a programmable poly-phase energy calculator IC that supports 1-, 2- or 3-phase WYE and Delta services, from 2 to 4 wires, computes cumulative active and reactive wide-band and fundamental harmonic energies, computes active and reactive energies, RMS and momentary voltage and current values for each phase, supports Rogowski coil, current transformer, Shunt or Hall current sensors, exclusive ripple-free energy calculation algorithm, programmable pulsed output, stepper motor outputs, neutral current, temperature, and magnetic field monitoring, OTP memory for configuration and calibration, SPI interface, supports IEC 62052-11 / 62053-21 / 62053-23 standards, less than 0.1 % error over 1:1000 dynamic range


STMicroelectronics STPMC1 Programmable Poly-phase Energy Calculator IC Datasheet - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
77
File format
PDF
File size
2.7 MB
Published
08 August, 2012
Updated
30 September, 2023
Model
STPMC1
MD5 checksum
BFA47CCFBFE3BE8E427ED1EE99DA045B

About this manual

The STPMC1 is an Application-Specific Standard Product (ASSP) designed for effective energy measurement in power line systems. It functions as an energy calculator capable of computing cumulative active and reactive wideband and fundamental harmonic energies, as well as RMS and momentary voltage and current values for each phase. The device supports various current sensors, including Rogowski coils, current transformers, shunts, and Hall sensors.

What's inside

  • Functional block diagram
  • Pin configuration
  • Maximum ratings
  • Functions
  • Application
  • Electrical characteristics
  • Theory of operation
  • Energy calculation algorithm
  • Package mechanical data
  • Revision history

Specifications

Order codeSTPMC1BTR
Temperature range- 40 to 85 °C
PackageTSSOP20
Packagingtape and reel
Parts per reel2500
Document ID15728
RevisionRev 6
Error over dynamic rangeLess than 0.1 %

Frequently asked questions

What services does the STPMC1 support?

The device supports 1-, 2- or 3-phase WYE and Delta services, from 2 to 4 wires.

What current sensors are supported?

The IC supports Rogowski coil, current transformer, Shunt or Hall current sensors.

What is the dynamic range error?

The device achieves less than 0.1 % error over a 1:1000 dynamic range.