This document is the installation instruction of SENTROL 2302 SERIES Curtain Door Magnetic Contact Models: 2302A, 2304A
This document provides installation instructions for the Sentrol 2302 Series Curtain Door Magnetic Contact, specifically models 2302A and 2304. It details how to mount the adjustable switch bracket housing onto a door channel, ensuring proper height relative to the floor (no more than 48 inches) and correct alignment with the actuating magnet.
| Model 2302 (Form A) Voltage | 100 V AC/DC max. |
|---|---|
| Model 2302 (Form A) Current | 0.5 A max. |
| Model 2304 (Form C) Voltage | 30 V AC/DC max. |
| Model 2304 (Form C) Current | 0.25 A max. |
The switch and bracket assembly should be no more than 48 inches from the surface of the floor.
The magnet end should be within 1/4 inch to 1/2 inch from the edge of the switch housing for reliable actuation.