The document is a user manual for a specific product, providing information on its features, installation and operation methods, as well as important safety instructions.
The Lab.gruppen fP 6400 is a professional power amplifier designed for use in 19-inch racks. This user manual covers unpacking, front and rear panel features, installation, and connection procedures. It details various operation modes including stereo, tandem, bridge mono, and impedance matching settings using MLS technology. The document also explains protection features such as clip limiting, thermal protection, and short circuit protection.
| Operating Temperature Limit | 90°C |
|---|---|
| VHF Protection Threshold | 12 kHz |
| Input Voltage Range | 100-120V |
| Safety Standard (US) | ANSI/UL 6500 |
| Safety Standard (Canada) | CSA E60065-00 |
No, the unit should not be used if the power cord is broken or frayed.
The over temperature protect indicator illuminates if the amplifier is going to operate above its maximum operating temperature of 90°C.
The VHF protect indicator illuminates and mutes the input if signals above 12 kHz are continuously present at full power.
You must connect only to AC power outlets rated 100-120V, 50-60Hz.