Analog Devices AD534 Internally Trimmed Precision IC Multiplier Datasheet

AD534 is a precision analog multiplier produced by AD. It uses internal trimming technology, with a maximum allowed error of ±0.25%. All input terminals (X, Y, and Z) are differential and high impedance, supporting [(X1-X2)(Y1-Y2)/10V]+Z2 transfer function. The input terminal supports ±10V input voltage, the gain can be adjusted by the external adjustable resistor, the gain range is 1-100, the noise design is 90µVrms, the working frequency is 10Hz to 10kHz, and has excellent long-term stability. AD534 is mainly used in high-quality analog signal processing, differential ratio and percentage computation, algebraic and trigonometric function synthesis, wideband, high peak rms-to-dc conversion, precise voltage controlled oscillator and filter.


Analog Devices AD534 Internally Trimmed Precision IC Multiplier Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
20
File format
PDF
File size
375 KB
Published
03 August, 2012
Updated
30 September, 2023
Model
AD534
MD5 checksum
5E6A9687D7401FCE710E9B6253B954AE

About this manual

The AD534 is a monolithic laser-trimmed four-quadrant multiplier divider designed for high-quality analog signal processing. It features fully differential, high-impedance operation on all inputs (X, Y, and Z) and offers a pretrimmed scale factor of 10 V, adjustable down to 3 V via an external resistor.

What's inside

  • Features
  • Applications
  • Functional Block Diagram
  • Specifications
  • Pin Configurations
  • Typical Performance Characteristics

Specifications

Maximum Multiplication Error (AD534L)+0.25%
Scale Factor10 V (adjustable down to 3 V)
Low Noise Design90 pV rms (10 Hz to 10 kHz)
Supply Voltage (Rated Performance)+/-15 V

Frequently asked questions

What is the maximum multiplication error for the AD534L?

The AD534L has a guaranteed maximum multiplication error of +0.25% without external trimming.

Can the scale factor be adjusted?