Pentair SpaBrite AquaLight Underwater Light Owner's Manual

This document is the owner's manual for SpaBrite® / AquaLight® Underwater Light, including important safety instructions and installation guidelines. The manual covers steps and technical data for installing the light fixture during new pool construction, replacing the fixture in an existing pool, and replacing the lamp only.


Pentair SpaBrite AquaLight Underwater Light Owner's Manual - cover page
Brand
Pentair
Category
Other
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
574 KB
Published
12 July, 2012
Updated
28 September, 2023
MD5 checksum
065966CCEFB774E3E4A9DE32B91C04FC

About this manual

This manual provides instructions for installing the SpaBrite AquaLight underwater light fixture during new pool construction and for replacing the fixture in an existing pool. It emphasizes safety precautions, including the requirement for installation by a licensed electrician and adherence to the National Electrical Code. Key steps involve ensuring proper electrical bonding, grounding, and the correct orientation of the wet niche before installing the light assembly.

What's inside

  • Installing Light Fixture During New Pool Construction
  • Replacing Light Fixture in Existing Pool
  • Replacing a Lamp Only
  • Technical Data
  • Important Safety Information
  • Risk of Electrical Shock
  • Wet Niche Installation Requirements
  • Circuit Breaker and GFCI Requirements

Frequently asked questions

What is the minimum distance the junction box must be from the pool edge?

The junction box must be located at least 48 inches from the edge of the pool.

How long must the cord be coiled around the light fixture?

You must leave at least four feet of cord at the light fixture to coil around it.

How long can the underwater light operate without being totally submerged?

Never operate the light for more than 10 seconds unless it is totally submerged in water.