Agilent 255 Dual Plasma Nitrogen Chemiluminescence Detector Application Note

This document discusses the uses and analysis methods of nitroaromatic compounds. Nitroaromatics are commonly used as solvents and precursors to high value organic compounds, and some are also explosive or precursors to explosives. The document addresses the limitations of analyzing nitroaromatics and recommends the use of the Agilent Dual Plasma Nitrogen Chemiluminescence Detector for detecting nitrogen-containing species.


Agilent 255 Dual Plasma Nitrogen Chemiluminescence Detector Application Note - cover page
Brand
Agilent
Category
Other Electronics
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
95 KB
Published
05 July, 2012
Updated
28 September, 2023
MD5 checksum
417B49E70166F406C96D214C0ABA27EE

About this manual

This document describes the analysis of nitroaromatics and explosive materials using Gas Chromatography (GC) coupled with an Agilent Dual Plasma Nitrogen Chemiluminescence Detector (NCD). It highlights the detector's high selectivity for nitrogen species, which allows for the detection of analytes in the presence of interfering carbon-based compounds and at lower elution temperatures than mass spectrometry.

The text provides a specific experimental setup involving an Agilent 6890 GC and a Restek Rtx-TNT column. It details the operating conditions, including injector and oven temperature programs, and presents chromatographic results for various nitroaromatic compounds and calibration mixtures, demonstrating sub-ng level detection capabilities.

What's inside

  • Introduction
  • Technical Overview
  • Experimental Conditions
  • Test Samples
  • Chromatogram Results

Specifications

Selectivity toward nitrogen speciesgreater than 10 over carbon
Detector operating environmentvacuum
Base temperature300 °C
Burner temperature900 °C
Oxygen flow rate8 SCCM
Hydrogen flow rate4 SCCM
Column length6 m
Column inner diameter0.63 mm
Column film thickness1.5 ym

Frequently asked questions

What is the selectivity of the Agilent 255 NCD detector?

The detector has high selectivity toward nitrogen species, greater than 10 over carbon.

What column was used for the nitroaromatics analysis?

A Restek Rtx-TNT column with a length of 6 m and an inner diameter of 0.63 mm was used.

What are the base and burner temperatures for the detector?

The base temperature is 300 °C and the burner temperature is 900 °C.