Agilent 5973Network Mass Selective Detector Manual

The 6890/5973N systems can be configured with additional accessories to adapt them for various applications. The MS Productivity ChemStation Data System can process data from both the MS and conventional GC detectors. Table 2 is a partial list of options that may be added to enhance the sample introduction, separation, and detection capabilities. Some of the accessories are provided by third-party channel partners who have been qualified by Agilent Technologies. Check with your local sales representative to discuss your exact needs and the availability of the accessories in your area.


Agilent 5973Network Mass Selective Detector Manual - cover page
Brand
Agilent
Category
Other Electronics
Document type
Product Leaflet
Language
English
Pages
9
File format
PDF
File size
202 KB
Published
04 July, 2012
Updated
29 September, 2023
MD5 checksum
748F2C8E012B5ECD95470E2EAC4F632C

About this manual

This document provides general technical information about the Agilent 5973N Network Mass Selective Detector (MSD), a transmission quadrupole mass spectrometer used for qualitative and quantitative analysis. It details the various system configurations available, including options for electron ionization (EI), positive chemical ionization (PCI), and negative chemical ionization (NCI). The text also lists compatible accessories for the 6890 GC system to enhance sample introduction and detection capabilities.

What's inside

  • General Description and Configurations
  • External Ionization Sources
  • Autosampler
  • Advanced Electronic Pneumatics Control
  • Independently Heated GC/MS Interface
  • Metallized Quadrupole
  • High Energy Dynode-Electron Multiplier Detector
  • LAN and Local Control Panel
  • Macro Language
  • Instrument Performance

Specifications

Quadrupole Materialsinglepiece of quartz
Detector Typeoff-axis high-energy-dynode electron multiplier (HED-EM)
Interface Length17-cm

Frequently asked questions

Can the 5973N be controlled remotely?

Yes, the system allows control from a Local Area Network (LAN) or via a Local Control Panel (LCP).

What ionization techniques can the 5973N perform?

The 5973N can perform electron ionization (EI), positive chemical ionization (PCI), and negative chemical ionization (NCI).

What is the length of the independently heated GC/MS interface?

The independently heated 17-cm interface is one of the shortest on any mass spectrometer.

How many samples can be automatically injected with just the autosampler tower?

Up to eight samples can be automatically injected with just the tower.