Agilent Fast Analysis of Tocopherol Phenolic Antioxidants Erucamide Slip Additives in Polypropylene Homopolymer Formulations Using 1200 Rapid Resolution Liquid Chromatography (RRLC) with Rapid R

This document describes the use of vitamin E (tocopherol), phenolic antioxidants, and erucamide slip additives in polypropylene homopolymer formulations, as well as their analysis and detection using liquid chromatography with ultraviolet/visible detection. The Agilent 1200 Rapid Resolution LC system with Agilent ZORBAX RRHT columns allows for rapid separation of these antioxidants with the same or improved resolution. The Agilent method translator can be used to convert the ASTM method into new methods based on instrument parameters, column dimensions, and particle size in three modes: simple conversion, speed optimized, and resolution optimized methods.


Agilent Fast Analysis of Tocopherol Phenolic Antioxidants Erucamide Slip Additives in Polypropylene Homopolymer Formulations Using 1200 Rapid Resolution Liquid Chromatography (RRLC) with Rapid R - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
10
File format
PDF
File size
448 KB
Published
02 July, 2012
Updated
28 September, 2023
MD5 checksum
12A5D45E61BB4F80CC411E53DEAFC8AF

About this manual

The document details a method for resolving Vitamin E, phenolic antioxidants, and erucamide slip additives in polypropylene homopolymer formulations. It compares the performance of Agilent ZORBAX Eclipse XDB-C18 and XDB-C8 stationary phases, concluding that the C8 phase offers better retention characteristics and peak shape.

The text explains how to use the Agilent Method Translator to convert conventional ASTM methods into new methods optimized for speed or resolution on sub-two-micron columns. It covers three conversion modes: simple conversion, speed optimization, and resolution optimization.

What's inside

  • Chemical Information of Antioxidants
  • Selection of Stationary Phase
  • Injection Volume Influence
  • Method Translator Versions
  • Sample Preparation
  • Simple Conversion Mode
  • Speed Optimized Conversion
  • Resolution Optimized Conversion

Specifications

System ComponentsG1379B micro vacuum degasser, G1312B binary pump SL, G1367C high-performance autosampler SL, G1316B thermostatted column compartment SL, G1315C UV/VIS diode array detector SL
Software VersionChemStation 32-bit version B.02.01-SR1
Mobile Phase Awater
Mobile Phase Bacetonitrile (ACN)
Flow Rate (Standard)1.5 mL/min
Wavelength200 nm

Frequently asked questions

Which stationary phase is recommended for better peak shape?

The ZORBAX Eclipse XDB-C8 column showed better retention capability and peak shape compared to the C18 column.

What is the effect of injection volume on real sample extraction?

An injection volume of 5 uL was found suitable to avoid solvent influence and peak splitting observed at 10 uL.

Download PDF (448 KB)