National Semiconductor LM112/LM212/LM312 Operational Amplifiers Datasheet

The LM112 series are micropower operational amplifiers with very low offset-voltage and input-current errors�at least a factor of ten better than FET amplifiers over a b55�C to a125�C temperature range


National Semiconductor LM112/LM212/LM312 Operational Amplifiers Datasheet - cover page
Brand
National Semiconductor
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
6
File format
PDF
File size
201 KB
Published
12 June, 2012
Updated
01 October, 2023
MD5 checksum
63EDE85C0FACE41564BA62D6B322AD43

About this manual

This document describes the LM112, LM212, and LM312 series of micropower operational amplifiers. These devices feature very low offset-voltage and input-current errors, with internal frequency compensation and provisions for offset adjustment. They are designed to operate on supply voltages ranging from +2V to +20V with a quiescent current of only 300 pA.

What's inside

  • General Description
  • Features
  • Connection Diagram
  • Absolute Maximum Ratings
  • Electrical Characteristics
  • Typical Performance Characteristics
  • Schematic Diagram
  • Physical Dimensions

Specifications

Supply Voltage+2V to +20V
Quiescent Current300 pA
Maximum Input Bias Current3 nA
Offset Currentless than 400 pA
Operating Temperature (LM112)-55°C to +125°C
Operating Temperature (LM212)-25°C to +85°C

Frequently asked questions

What is the quiescent current of the LM112 series?

The quiescent current is only 300 pA.

Can these amplifiers operate from a single supply?

Yes, they can be run from a single supply like 5V.

What is the maximum supply voltage?

The maximum supply voltage is +20V.