Agilent Analysis of Color Additives in Sweets Application Note

This study presents a robust reverse phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of 10 synthetic colorants in sweets. Separation and quantification were achieved using an Agilent Poroshell EC-C18 column and an Agilent 1260 Infinity LC System. The robustness of the method was established through partial validation. The suitability of this method for quantifying artificial colorants from a food matrix was demonstrated by analyzing color additives in sweets. Additionally, the HPLC method was successfully transferred to a short Ultra High Pressure Liquid Chromatographic (UHPLC) method using an Agilent 1290 Infinity LC System for faster analysis without compromising resolution. The Agilent 1290 Infinity Diode Array Detector (DAD) was used to select various wavelengths for quantifying different colorants at their absorbance maxima. The limits of detection (LOD), limits of quantification (LOQ), precision, accuracy, and linearity of each colorant were established using both methods. Incorporating the Agilent 7696A Sample Prep WorkBench into the analytical workflow facilitated sample preparation for LOD, LOQ, and linearity studies.


Agilent Analysis of Color Additives in Sweets Application Note - cover page
Brand
Agilent
Document type
Application Note
Language
English
Pages
12
File format
PDF
File size
1.4 MB
Published
11 June, 2012
Updated
28 September, 2023
MD5 checksum
05298EB99FAE32B0FA816C5989F3B107

About this manual

The document details a robust reverse phase high performance liquid chromatographic (RP-HPLC) method developed by Agilent Technologies for the simultaneous determination of ten synthetic colorants. The study utilizes an Agilent 1260 Infinity LC System with a Poroshell EC-C18 column to achieve separation and quantification.

What's inside

  • Introduction
  • Instruments and software
  • Reagents and materials
  • Chromatographic parameters
  • Sample preparation for color quantification and recovery studies

Frequently asked questions

What is the purpose of this application note?

This document describes a robust reverse phase high performance liquid chromatographic method for the simultaneous determination of 10 synthetic colorants in sweets.

What are the dimensions of the column used for the HPLC analysis?

The Agilent Poroshell 120 EC-C18 column used for the HPLC analysis has dimensions of 4.6 x 150 mm.

What is the flow rate for the UHPLC analysis?

The flow rate for the UHPLC analysis is 0.7 mL/min.