SICK W 27-2 Photoelectric Proximity Switches Datasheet

W 27-2 photoelectric switch series with expanded possibilities


SICK W 27-2 Photoelectric Proximity Switches Datasheet - cover page
Brand
SICK
Category
Industrial Supply
Document type
Datasheet
Language
English
Pages
32
File format
PDF
File size
1.4 MB
Published
09 May, 2012
Updated
30 September, 2023
MD5 checksum
8CF3973DEF522E07CE0C4BD956DF2F2D

About this manual

The W 27-2 series from SICK covers photoelectric proximity, reflex and through‑beam switches. All devices share a fully welded ABS housing, background suppression and modular design, allowing a wide range of sensor configurations.

Variants differ by light source (infrared, red LED laser, visible laser) and scanning distance (100 mm to 1 500 mm). Optional accessories such as connectors, mounting systems and heated reflectors are listed, and the series supports AS‑i integration for intelligent sensor networks.

What's inside

  • Technical data
  • Scanning distance
  • Light source
  • Supply voltage
  • Ambient temperature
  • Enclosure rating
  • Output current
  • Accessories
  • Order information

Specifications

Scanning distance100 mm … 1 500 mm (adjustable)
Light sourceLED laser, red light
Supply voltage10 V … 30 V DC (or 24 V … 240 V UC)
Ambient temperature (operation)-10 °C … +45 °C
Enclosure ratingIP 67
Output current (max)100 mA
Weight≈ 100 g

Frequently asked questions

What is the scanning distance range for the WT 27-2 series?

The WT 27-2 series offers an adjustable scanning distance from 100 mm up to 1 500 mm depending on the model.

What supply voltage does the W 27-2 series accept?

The series can be powered with 10 V to 30 V DC or with 24 V to 240 V UC, depending on the variant.

What is the enclosure protection rating of these switches?

All W 27-2 switches have an IP 67 protection rating.

Are there optional accessories available for the W 27-2 series?

Yes, optional accessories include various connectors, mounting systems, reflectors and heating elements.