The Maxim MAX3386E is a 3 V‑powered RS‑232 transceiver designed for low‑power handheld devices such as PDAs and cell phones. It integrates two receivers and three transmitters, including a dedicated ring‑indicator transmitter, and features a VL pin that allows operation with mixed‑voltage logic levels.

The device provides robust ESD protection (±25 kV air‑gap, ±15 kV human‑body, ±8 kV contact), operates from a 20‑pin TSSOP package, and supports data rates up to 250 kbps with a typical supply current of 300 µA (less than 1 µA in shutdown).

What's inside

  • General Description
  • Absolute Maximum Ratings
  • DC Electrical Characteristics
  • Timing Characteristics
  • Typical Operating Characteristics
  • Pin Description
  • VL Logic Supply Input
  • ESD Protection
  • Applications

Specifications

Supply Voltage (VCC)+3.0 V to +5.5 V
Maximum Data Rate250 kbps
Supply Current (normal operation)300 µA
ESD Protection±25 kV IEC 1000‑4‑2 Air‑Gap, ±15 kV Human Body Model, ±8 kV Contact Discharge
Package20‑pin TSSOP
Operating Temperature Range-40 °C to +85 °C
Receivers / Transmitters2 receivers, 3 transmitters
VL Pin Logic Supply Range1.8 V ≤ VL ≤ VCC

Frequently asked questions

What is the maximum data rate of the MAX3386E?

It can operate at data rates up to 250 kbps while maintaining RS‑232 compliant output levels.

What supply voltage does the MAX3386E require?

The device works from a supply voltage of +3.0 V to +5.5 V.

How much supply current does the MAX3386E draw in normal operation?

Typical supply current is about 300 µA.

What ESD protection levels does the MAX3386E provide?

It offers ±25 kV IEC 1000‑4‑2 air‑gap, ±15 kV human‑body model, and ±8 kV contact‑discharge protection on all RS‑232 pins.