Seoul Semiconductor LM560A LED Datasheet

This document is a technical data sheet for the Z-Power LED X10490 series, describing the features and applications of the product, including absolute maximum ratings, electrical characteristics, outline dimensions, optical characteristics, color and binning, packaging, soldering, precautions for use, and reliability testing.


Seoul Semiconductor LM560A LED Datasheet - cover page
Brand
SEOUL
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
19
File format
PDF
File size
686 KB
Published
04 May, 2012
Updated
29 September, 2023
Model
LM560A
MD5 checksum
6BC7A1D51EC2551874C9CD0F6D7F483B

About this manual

This handbook details the LM560A Lamp LED series, including its full code, features, and typical applications such as outdoor signage, traffic signals, and backlighting. It lists absolute maximum ratings, electrical characteristics, outline dimensions, optical characteristics, color and binning information, and packaging details.

Reliability testing procedures, handling precautions, and recommended soldering conditions are also covered, along with graphs of forward voltage, luminous intensity, radiation diagrams, and wavelength spectra.

What's inside

  • Full code of Lamp LED series
  • Feature & Application
  • Absolute Maximum Ratings
  • Electrical Characteristics
  • Outline Dimension
  • Optical Characteristics
  • Color & Binning
  • Packing
  • Soldering
  • Precaution for use

Specifications

DC Forward Current30 mA
Forward Peak Pulse Current100 mA
Reverse Voltage5 V
Power Dissipation114 mW
Operating Temperature-35 ~ 85 °C
Storage Temperature-40 ~ 100 °C
Solder Temperature260°C for 10 seconds
Luminous Intensity (typical)1650 – 2500 mcd
Chromaticity Coordinatesx=0.45, y=0.41
Forward Voltage (typical)3.3 – 3.8 V
Viewing Angle60°

Frequently asked questions

What is the maximum DC forward current for the LM560A?

The LM560A can handle a DC forward current of up to 30 mA.

What is the typical forward voltage of the LM560A at 20 mA?

At 20 mA the forward voltage is typically between 3.3 V and 3.8 V.

What temperature range is recommended for operating the LM560A?

The device is rated for operation from –35 °C up to 85 °C.

Download PDF (686 KB)