ABB B84143-A600-S9 (10025451) RFI filter Technical Note

This Technical Note provides information about a problem with the RFI filter B84143-A600-S9 (10025451) and the corrective actions required to avoid personal injury.


ABB B84143-A600-S9 (10025451) RFI filter Technical Note - cover page
Brand
ABB
Category
Other
Document type
Service Manual
Language
English
Pages
2
File format
PDF
File size
55 KB
Published
22 March, 2012
Updated
30 September, 2023
MD5 checksum
BEC25F182BD158425856DFEEE7791920

About this manual

This technical note from ABB Oy describes an RFI filter (B84143-A600-S9) used at the input of SAMI STAR and ACS 600 frequency converters to limit conducted emissions. It warns of potential capacitor deformation and explosion risks during installations between 1996-2000, requiring immediate removal if deformed.

The document provides corrective actions including visual inspection procedures and replacement with a new Epcos RFI filter, emphasizing that replacement requires mechanical engineering verification and compliance with new filter specifications.

What's inside

  • Technical Note RFI filter B84143-A600-S9
  • DOCTNACS60019
  • SAMI STAR frequency converters
  • ACS 600 frequency converters
  • Capacitor deformation
  • Filter replacement
  • Epcos RFI filter

Specifications

Filter typeRFI filter
Filter componentschokes and capacitors
Capacitor connectionsbetween the phases and virtual star point and also between star point and ground
Affected modelsSAMI STAR 200F380 - 400F380, SAMI STAR 250F500 - 500F500, SAMI STAR 200F690 - 630F690, ACS607-0210-3 - ACS607-0610-6

Frequently asked questions

What is the purpose of the RFI filter?

The RFI filter is used at the input of SAMI STAR and ACS 600 frequency converters to fulfill requirements to limit conducted emissions.

What are the risks if the RFI filter capacitor is defective?

A defective filter capacitor can cause deformation to the RFI filter and may lead to explosion without safety vents, potentially causing personal injuries.

What is the corrective action for a deformed RFI filter?

Remove the RFI filter immediately and run the system without it as a temporary solution.