Dilong DAD-V4 Module Power Supply Datasheet

This document introduces the technical parameters and features of the DAD-V4 series AC/DC module power supply with dual output of 25W. The product has two naming methods: dual-route common ground output and dual-route isolated voltage-stabilizing output, with built-in input filtering circuit and FCI filtering method. The input voltage range is AC165~265V or AC85~265V, and the output voltage can be selected as DC 3.3V, 5V, 12V, 15V, 24V, 28V, 48V or 110V, with high voltage accuracy and low ripple and noise. The product also features multiple protection functions, shock resistance design, and electromagnetic compatibility design.


Dilong DAD-V4 Module Power Supply Datasheet - cover page
Brand
石家庄迪龙
Category
AC-DC Power
Document type
Datasheet
Language
Chinese
Pages
1
File format
PDF
File size
126 KB
Published
23 December, 2011
Updated
28 September, 2023
MD5 checksum
37BE0A317614ED39B9885C448483A5F6

About this manual

This datasheet describes the technical parameters of the Dilong DAD-V4 series 25 W module power supply, including input voltage ranges, selectable output voltages, accuracy, efficiency, and protection features. It also lists environmental specifications, mechanical dimensions, and pin assignments.

Key features include dual‑output configurations (isolated or common‑ground), high efficiency (>75%), over‑current protection, strong isolation (up to 1500 VAC), and compliance with IEC and UL standards for industrial and military applications. This manual is written in Chinese.

What's inside

  • Technical Parameters
  • Input and Output Voltage
  • Efficiency and Power
  • Protection Features
  • Environmental Conditions
  • Mechanical Dimensions
  • Pin Configuration
  • Compliance and Standards

Specifications

Voltage accuracyVo1 ±1 %, Vo2 ±3 %
Over‑current protection>120 % of rated current
Isolation resistance>100 MΩ
Isolation voltageVin‑Vo >1500 VAC, Vo‑FG >1500 VAC, Vo‑FG >500 VDC
Operating temperature (industrial)-25 °C to +55 °C
Storage temperature (industrial)-40 °C to +105 °C
Operating humidity5 %–85 % RH
Shock resistance5 g, 8–12 ms
Cooling methodNatural air cooling
Housing materialLow‑radiation plastic

Frequently asked questions

What protection features are provided?

The unit includes over‑current protection (>120 % of rated current), isolation resistance >100 MΩ, and isolation voltage up to 1500 VAC (or 500 VDC).

What are the operating temperature limits for industrial use?

The device operates from –25 °C to +55 °C in industrial environments.