Plasmacluster Ion Generator is a Plasmacluster HD antibacterial machine produced by Sharp Corporation. It can kill airborne mold, viruses, allergens and adhering odor by releasing plasma ions.
This manual explains how to install the Sharp IG‑A10A Plasmacluster Ion Generator, including placement guidelines, power requirements, and safety precautions. It describes the front and back parts, operation modes, and how to adjust the ion output.
The guide also covers routine cleaning of the main unit and filter, replacement of the Plasmacluster Ion Generating Unit, detailed specifications, and a troubleshooting chart for common problems.
| Power supply | 220‑240 V, 50/60 Hz |
|---|---|
| Power consumption (High) | 14.0 W |
| Operating noise level (High) | 44 dBA |
| Outer dimensions (W × D × H) | 140 × 160 × 345 mm |
It should be replaced approximately every 2 years (about 17,500 hours) of continuous operation; the unit will stop after about 26 months (19,000 hours) if not replaced.
First check that the power plug is inserted; if the unit has been used for about 2 years 2 months, replace the ion‑generating unit, otherwise press the operation button to restart.
Clean the filter every two weeks or more often if needed, gently removing dust with a vacuum cleaner; for stubborn dirt detach the filter and wash with water and mild detergent, then dry.
Place the unit at least 2 m away from equipment that uses electric waves such as televisions or radios to avoid interference.