YUDO STEC-NA2 Error 065: Operation alarm

YUDO STEC-NA2 · taken from the manufacturer’s manual, pages cited

Alarm code065

Code 065 is an Operation alarm indicating a posture axis cycle timeout because the posture axis did not move to the set value. The manual's first action is: “Please check the overall speed and the speed settings for each point. Please check the setting value of the cycle monitor timer (T23).”

Model
YUDO STEC-NA2
Display shows
Operation alarm (065)
Type
Alarm code
Source
Manual p. 69

What 065 means

Operation alarm p. 69

Common causes

  • Cycle timeout posture axis Cycle timeout posture axis did not move to the set value p. 69

What to do

  1. Please check the overall speed and the speed settings for each point. Please check the setting value of the cycle monitor timer (T23). p. 69

Before you service the product, read the safety instructions in the manual p. 9.

If 065 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact YUDO service.