YUDO STEC-NA2 Error 42: Limit Switch Abnormality

YUDO STEC-NA2 · taken from the manufacturer’s manual, pages cited

Error code42

Code 42 is a Limit Switch Abnormality indicating that Drop-side Area Program Limit and Mold Opened Limit are both OFF. The manual's first action is: “Injection molding machine input abnormality. Please inspect the wiring of the mold opened signal and the continuous signal between the injection molding machine and the take-out machine.”

Model
YUDO STEC-NA2
Display shows
Limit Switch Abnormality (42)
Type
Error code
Source
Manual p. 68

What 42 means

Limit Switch Abnormality p. 68

Common causes

  • Drop-side Area Program Limit and Mold Opened Limit both OFF p. 68

What to do

  1. Injection molding machine input abnormality. Please inspect the wiring of the mold opened signal and the continuous signal between the injection molding machine and the take-out machine. p. 68

Before you service the product, read the safety instructions in the manual p. 9.

If 42 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact YUDO service.