YUDO STEC-NA2 Error 068: Operation alarm

YUDO STEC-NA2 · taken from the manufacturer’s manual, pages cited

Alarm code068

Code 068 is an Operation alarm indicating a posture return limit cycle timeout because the posture return limit (L8) is not ON. The manual's first action is: “Confirm the operation of the posture cylinder by manual operation, please adjust the speed of the posture return speed control valve, and inspect the operating status and wiring of the L8 limit switch.”

Model
YUDO STEC-NA2
Display shows
Operation alarm (068)
Type
Alarm code
Source
Manual p. 69

What 068 means

Operation alarm p. 69

Common causes

  • Cycle timeout posture return limit Cycle timeout posture return limit (L8) is not ON p. 69

What to do

  1. Confirm the operation of the posture cylinder by manual operation, please adjust the speed of the posture return speed control valve, and inspect the operating status and wiring of the L8 limit switch. p. 69

Before you service the product, read the safety instructions in the manual p. 9.

If 068 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact YUDO service.

This page summarises what the manufacturer’s manual says about 068; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YUDO. Found a mistake? Report an error.