YUDO STEC-NA2 Error 071: Operation alarm

YUDO STEC-NA2 · taken from the manufacturer’s manual, pages cited

Alarm code071

Code 071 is an Operation alarm indicating an ejector pin advance limit cycle timeout because the ejector pin advance limit (ME) is not ON. The manual's first action is: “Please confirm the ejector pin operation by manual operation, and inspect the operating status and wiring of the ME limit switch. If there is no abnormality on the injection molding machine side, please inspect the signal interlock wiring between the injection molding machine and the take-out machine.”

Model
YUDO STEC-NA2
Display shows
Operation alarm (071)
Type
Alarm code
Source
Manual p. 69

What 071 means

Operation alarm p. 69

Common causes

  • Cycle timeout ejector pin advance limit Cycle timeout ejector pin advance limit (ME) is not ON p. 69

What to do

  1. Please confirm the ejector pin operation by manual operation, and inspect the operating status and wiring of the ME limit switch. If there is no abnormality on the injection molding machine side, please inspect the signal interlock wiring between the injection molding machine and the take-out machine. p. 69

Before you service the product, read the safety instructions in the manual p. 9.

If 071 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact YUDO service.