Yaskawa Varispeed E7 CIMR-E7B Error OH4: Motor Overheat (PTC Analog Input)

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Fault codeOH4

Motor Overheat (PTC Analog Input) means the motor overheat condition occurs according to the setting of L1-04. The manual's first action is: “The inverter will stop. Fault contact is activated.”

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
Motor Overheat (PTC Analog Input) (OH4)
Type
Fault code
Source
Manual p. 172

What OH4 means

Motor Overheat (PTC Analog Input) p. 172

Common causes

  • According to the setting of L1-04 p. 172
  • Motor overheat p. 172

What to do

  1. The inverter will stop. Fault contact is activated. p. 172
  2. Reset the load size, acceleration time, and cycle time. Reset the V/f characteristic. Verify the motor temperature input from terminal A2. Verify the setting of E2-01 (motor rated current). p. 172

Before you service the product, read the safety instructions in the manual p. 4.

If OH4 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about OH4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.