Yaskawa Varispeed E7 CIMR-E7B Error OH3: Motor Overheat Warning (PTC Analog Input)

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Warning codeOH3

Motor Overheat Warning (PTC Analog Input) means the motor overheat condition occurs when the input motor temperature exceeds the alarm detection value according to the setting of L1-03. The manual's first action is: “The inverter stops or continues running.”

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
Motor Overheat Warning (PTC Analog Input) (OH3)
Type
Warning code
Source
Manual p. 172

What OH3 means

Motor Overheat Warning (PTC Analog Input) p. 172

Common causes

  • According to the setting of L1-03 p. 172
  • Motor overheat p. 172
  • Motor overheat: H3-09 is set to E, and the input motor temperature (thermistor) exceeds the alarm detection value. p. 172

What to do

  1. The inverter stops or continues running. p. 172
  2. Reset the load size, acceleration time, and cycle time. Reset the V/f characteristic. Verify the motor temperature input from terminal A2. Verify the setting of E2-01 (motor rated current). p. 172
  3. Motor overheat. Reset the load size, acceleration/deceleration time, and cycle time. Reset the V/f characteristic. Verify the motor temperature input from terminal A2. p. 172

Before you service the product, read the safety instructions in the manual p. 4.

If OH3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about OH3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.