Yaskawa Varispeed E7 CIMR-E7B Error EF: Forward and reverse commands input simultaneously (forward and reverse commands entered simultaneously for more than 0.5 seconds)

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Alarm codeEF

Forward and reverse commands input simultaneously occurs when forward and reverse commands are entered simultaneously for more than 0.5 seconds. The manual's first action is: “Reset the order of forward and reverse commands. When this alarm occurs, the motor will decelerate and stop (because the rotation direction is ambiguous).”

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
EF
Type
Alarm code
Source
Manual p. 259

What EF means

Forward and reverse commands input simultaneously (forward and reverse commands entered simultaneously for more than 0.5 seconds) p. 259

Common causes

  • Forward and reverse commands input simultaneously (forward and reverse commands entered simultaneously for more than 0.5 seconds) p. 259

What to do

  1. Reset the order of forward and reverse commands. When this alarm occurs, the motor will decelerate and stop (because the rotation direction is ambiguous). p. 259

Before you service the product, read the safety instructions in the manual p. 4.

If EF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about EF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.