YASKAWA III series SGM/SGDS Error A 830: Encoder battery alarm

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA 830

Encoder battery alarm means the backup battery voltage of the absolute encoder has dropped. The manual's first action is: “Dynamic brake stop”

Model
YASKAWA III series SGM/SGDS
Display shows
Encoder battery alarm (A 830)
Type
Alarm code
Source
Manual p. 290

What A 830 means

Encoder battery alarm p. 290

Common causes

  • Backup battery voltage of absolute encoder has dropped p. 290
  • Occurs when control power is turned on (parameter Pn002.2 = 1) p. 290
  • Occurs when control power is turned on (parameter Pn002.2 = 0) when used with an absolute encoder p. 290
  • Battery voltage is below the specified value (2.7 V) p. 290
  • Servo unit circuit board fault p. 290

What to do

  1. Dynamic brake stop p. 290
  2. Replace the servo unit p. 290
  3. Connect the battery correctly p. 290
  4. Replace the battery and restart the PG power p. 290

Before you service the product, read the safety instructions in the manual p. 292.

If A 830 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A 830; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.