Alarm code1837
The 24V safety power supply has failed due to a connection issue. The manual's first action is: “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”
- Model
- Yaskawa FS100
- Display shows
- M-SAFETY 24V POWER SUPPLY ERROR (1837)
- Type
- Alarm code
- Source
- Manual p. 152
What 1837 means
M-SAFETY 24V POWER SUPPLY ERROR p. 152
Common causes
- Connection failure p. 152
What to do
- (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 152
If 1837 is still not resolved
- (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 152 “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”
This page summarises what the manufacturer’s manual says about 1837; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.