Xinling XLP3200T Error E-05: Overvoltage during deceleration

Frequency inverter · taken from the manufacturer’s manual, pages cited

Error codeE-05

This code means overvoltage during deceleration due to deceleration time too short, regenerative load present, or input voltage abnormal. The manual's first action is: “Extend deceleration time”

Model
Xinling XLP3200T
Display shows
Overvoltage during deceleration (E-05)
Type
Error code
Source
Manual p. 18

What E-05 means

Overvoltage during deceleration p. 50

Common causes

  • Deceleration time too short p. 50
  • Regenerative load present p. 50
  • Input voltage abnormal p. 50

What to do

  1. Extend deceleration time p. 50
  2. Consider using an energy-dissipation braking component p. 50
  3. Check input power supply p. 50

Before you service the product, read the safety instructions in the manual p. 3.

If E-05 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Xinling service.

This page summarises what the manufacturer’s manual says about E-05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Xinling. Found a mistake? Report an error.