Xinling XLP3200T Error E-02: Overcurrent during deceleration

Frequency inverter · taken from the manufacturer’s manual, pages cited

Error codeE-02

This code means overcurrent during deceleration due to deceleration time too short, inverter power rating too small, or large inertia load present. The manual's first action is: “Extend deceleration time”

Model
Xinling XLP3200T
Display shows
Overcurrent during deceleration (E-02)
Type
Error code
Source
Manual p. 18

What E-02 means

Overcurrent during deceleration p. 50

Common causes

  • Deceleration time too short p. 50
  • Inverter power rating too small p. 50
  • Large inertia load present p. 50

What to do

  1. Extend deceleration time p. 50
  2. Select an inverter with a larger power rating p. 50
  3. Reduce load inertia or extend deceleration time p. 50

Before you service the product, read the safety instructions in the manual p. 3.

If E-02 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Xinling service.

This page summarises what the manufacturer’s manual says about E-02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Xinling. Found a mistake? Report an error.