Xinling XLP3200T Error E-01: Overcurrent during acceleration

Frequency inverter · taken from the manufacturer’s manual, pages cited

Error codeE-01

This code means overcurrent during acceleration due to acceleration time too short, grid voltage too low, or restarting a rotating motor. The manual's first action is: “Extend acceleration time”

Model
Xinling XLP3200T
Display shows
Overcurrent during acceleration (E-01)
Type
Error code
Source
Manual p. 18

What E-01 means

Overcurrent during acceleration p. 50

Common causes

  • Acceleration time too short p. 50
  • Grid voltage too low p. 50
  • Restarting a rotating motor p. 50
  • Inverter power rating too small p. 50
  • V/F curve unsuitable p. 50
  • Load inertia too large p. 50

What to do

  1. Extend acceleration time p. 50
  2. Check input power supply p. 50
  3. Set to DC braking first, then restart p. 50
  4. Select an inverter with a larger power rating p. 50
  5. Adjust V/F curve settings and torque boost amount p. 50
  6. Reduce load inertia or extend acceleration time p. 50

Before you service the product, read the safety instructions in the manual p. 3.

If E-01 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Xinling service.

This page summarises what the manufacturer’s manual says about E-01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Xinling. Found a mistake? Report an error.