Ekn3 indicates a motor constant setting error where some items indicated on the motor nameplate are not entered correctly, including base frequency H1, base frequency voltage H2, motor rated capacity F4B5, motor rated current F4B6, or motor rated speed F4B7. The manual's first action is: “Make sure that all items on the motor nameplate are entered correctly.”
- Model
- Toshiba VF-AS1
- Display shows
- Motor constant setting error (Ekn3)
- Type
- Error code
- Source
- Manual p. 297
What Ekn3 means
Motor constant setting error p. 297
Common causes
- Some items indicated on the motor nameplate are not entered correctly. Base frequency H1. Base frequency voltage H2. Motor rated capacity F4B5. Motor rated current F4B6. Motor rated speed F4B7. p. 297
What to do
- Make sure that all items on the motor nameplate are entered correctly. p. 297
Before you service the product, read the safety instructions in the manual p. 17.
If Ekn3 is still not resolved
- Read the Instruction Manual p. 17 “Read the Instruction Manual.”
This page summarises what the manufacturer’s manual says about Ekn3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Toshiba. Found a mistake? Report an error.