Taian Technology S310-201-H1BCD Error OC-S: Overcurrent at start‑up

Motor driver · taken from the manufacturer’s manual, pages cited

Error codeOC-S

Overcurrent at start-up means motor winding shorted to chassis, motor wiring shorted to ground, or an IGBT module damaged. The manual's first action is: “1. Service the motor”

Model
Taian Technology S310-201-H1BCD
Display shows
Overcurrent at start‑up (OC-S)
Type
Error code
Source
Manual p. 46

What OC-S means

Overcurrent at start‑up p. 46

Common causes

  • 1. Motor winding shorted to chassis p. 46
  • 2. Motor wiring shorted to ground p. 46
  • 3. IGBT module damaged p. 46

What to do

  1. 1. Service the motor p. 46
  2. 2. Inspect wiring p. 46
  3. 3. Replace IGBT module p. 46

Before you service the product, read the safety instructions in the manual p. 7.

If OC-S is still not resolved

  • Contact Taian Technology regional dealers or company technical personnel for difficult problems. p. 5
    “当您在使用过程中发现疑难问题时,请与台安科技各地区经销商或本公司技术人员 联系”

This page summarises what the manufacturer’s manual says about OC-S; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian Technology. Found a mistake? Report an error.