Taian Technology S310-201-H1BCD Error -LV-: Voltage too low while stopped

Motor driver · taken from the manufacturer’s manual, pages cited

Fault code-LV-

Voltage too low while stopped means power supply voltage too low, current-limiting resistor or fuse blown, or a detection line fault. The manual's first action is: “1. Check whether the power supply voltage is normal”

Model
Taian Technology S310-201-H1BCD
Display shows
Voltage too low while stopped (-LV-)
Type
Fault code
Source
Manual p. 46

What -LV- means

Voltage too low while stopped p. 46

Common causes

  • 1. Power supply voltage too low p. 46
  • 2. Current‑limiting resistor (R1) or fuse blown p. 46
  • 3. Detection line fault p. 46

What to do

  1. 1. Check whether the power supply voltage is normal p. 46
  2. 2. Replace or repair the current‑limiting resistor or fuse p. 46
  3. 3. Send inverter for repair p. 46

Before you service the product, read the safety instructions in the manual p. 7.

If -LV- is still not resolved

  • Contact Taian Technology regional dealers or company technical personnel for difficult problems. p. 5
    “当您在使用过程中发现疑难问题时,请与台安科技各地区经销商或本公司技术人员 联系”

This page summarises what the manufacturer’s manual says about -LV-; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian Technology. Found a mistake? Report an error.