Siemens SINAMICS V90, SIMOTICS S-1FL6 Error A7805: Power unit overload I²t

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Alarm codeA7805

Power unit overload I²t when the alarm threshold for power unit overload has been exceeded. The manual's first action is: “Reduce the continuous load.”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
Power unit overload I²t (A7805)
Type
Alarm code
Source
Manual p. 311

What A7805 means

Power unit overload I²t p. 311

Common causes

  • Alarm threshold for Pt overload of the power unit exceeded. p. 311

What to do

  1. Reduce the continuous load. p. 311
  2. Adapt the load duty cycle. p. 311
  3. Check the assignment of the rated currents of the motor and motor module. p. 311

Before you service the product, read the safety instructions in the manual p. 2.

If A7805 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about A7805; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.