Siemens SINAMICS V90, SIMOTICS S-1FL6 Error A7456: EPOS: Setpoint velocity limited

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Alarm codeA7456

The actual setpoint velocity exceeds the parameterized maximum velocity limit and has been internally restricted. The manual's first action is: “Check the entered setpoint velocity.”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
EPOS: Setpoint velocity limited (A7456)
Type
Alarm code
Source
Manual p. 307

What A7456 means

EPOS: Setpoint velocity limited p. 307

Common causes

  • The actual setpoint velocity is greater than the parameterized maximum velocity (p2571) and is therefore limited. p. 307

What to do

  1. Check the entered setpoint velocity. p. 307
  2. Reduce the velocity override. p. 307
  3. Increase the maximum velocity (p2571). p. 307
  4. Check the signal source for the externally limited velocity. p. 307

Before you service the product, read the safety instructions in the manual p. 2.

If A7456 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about A7456; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.