Fault codeA30016
Load supply switched off because the DC link voltage is too low. The manual's first action is: “Switch on the load supply.”
- Model
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Display shows
- Load supply switched off (A30016)
- Type
- Fault code
- Source
- Manual p. 312
What A30016 means
Load supply switched off p. 312
Common causes
- The DC link voltage is too low. p. 312
What to do
Before you service the product, read the safety instructions in the manual p. 2.
If A30016 is still not resolved
- Contact service / dealer for assistance p. 2 “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
- Contact service / dealer for assistance p. 13 “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”
This page summarises what the manufacturer’s manual says about A30016; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.