Siemens MICROMASTER 440 Error P0949

Siemens MICROMASTER 440 variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeP0949

The encoder channel A or B speed signals have been lost, either at high or low speed, depending on the value. The manual lists no action for this code.

Model
Siemens MICROMASTER 440
Display shows
P0949
Type
Error code
Source
Manual p. 432

What P0949 means

P0949 = 1 indicates that at high speed the encoder channel A or channel B, or both A and B speed signals have been lost (shaft speed > P0492). p. 432

Common causes

  • P0949 = 1 indicates that at high speed the encoder channel A or channel B, or both A and B speed signals have been lost (shaft speed > P0492). p. 432
  • P0949 = 2 indicates that at low speed the encoder channel A or both A and B speed signals have been lost (shaft speed < P0492). p. 432
  • P0949 = 3 indicates that at low speed the encoder channel B speed signal has been lost (shaft speed < P0492). p. 432

If P0949 is still not resolved

  • contact the dealer or service center p. 6
    “如果不遵守有关要求 不采取相应 措施 就会造成死亡或严重的人身伤害”
  • contact the dealer or service center p. 7
    “请仔细阅读这些“警告”,“注意”和“提示””

This page summarises what the manufacturer’s manual says about P0949; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.