Siemens MICROMASTER 440 Error A0810: DC Bus Maximum Voltage Vdc-max Controller Not Activated

Siemens MICROMASTER 440 variable frequency drive · taken from the manufacturer’s manual, pages cited

Alarm codeA0810

A0810 on the Siemens MICROMASTER 440 is listed in the manual as: DC Bus Maximum Voltage Vdc-max Controller Not Activated. The manual's first action is: “Check the following: 1. Input supply voltage (P0756) must be within the allowed range. 2. The load must be matched.”

Model
Siemens MICROMASTER 440
Display shows
DC Bus Maximum Voltage Vdc-max Controller Not Activated (A0810)
Type
Alarm code
Source
Manual p. 101

What A0810 means

DC Bus Maximum Voltage Vdc-max Controller Not Activated p. 101

Common causes

  • The DC bus maximum voltage Vdc-max controller is not activated because the controller cannot keep the DC bus voltage (r0026) within the range specified by (P2172). p. 101
  • If the supply voltage (P0210) remains too high, this alarm may occur. p. 101
  • If the motor is driven by the load, causing it to operate in regenerative braking mode, this alarm may occur. p. 101
  • During a down‑ramp, if the load inertia is especially large, this alarm may occur. p. 101

What to do

  1. Check the following: 1. Input supply voltage (P0756) must be within the allowed range. 2. The load must be matched. p. 101

Before you service the product, read the safety instructions in the manual p. 7.

If A0810 is still not resolved

  • contact the dealer or service center p. 6
    “如果不遵守有关要求 不采取相应 措施 就会造成死亡或严重的人身伤害”
  • contact the dealer or service center p. 7
    “请仔细阅读这些“警告”,“注意”和“提示””

This page summarises what the manufacturer’s manual says about A0810; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.