Error codeA0811
The DC bus maximum voltage Vdc-max controller has been activated, automatically increasing the down-ramp time to keep the DC bus voltage within the limit. The manual lists no action for this code.
- Model
- Siemens MICROMASTER 440
- Display shows
- DC Bus Maximum Voltage Vdc-max Controller Activated (A0811)
- Type
- Error code
- Source
- Manual p. 101
What A0811 means
DC Bus Maximum Voltage Vdc-max Controller Activated p. 101
Common causes
- The DC bus maximum voltage Vdc-max controller has been activated; therefore, the down‑ramp time will automatically increase, thereby automatically keeping the DC bus voltage (r0028) within the limit value (P2172). p. 101
If A0811 is still not resolved
This page summarises what the manufacturer’s manual says about A0811; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.