Fault codeF0042

Speed Control Optimization Function Fault means the speed control optimization function (P1960) fault, steady‑state speed not reached within the specified time, or reading is illogical. The manual's first action is: “Off2”

Model
Siemens MICROMASTER 430
Display shows
Speed Control Optimization Function Fault (F0042)
Type
Fault code
Source
Manual p. 86

What F0042 means

Speed Control Optimization Function Fault p. 86

Common causes

  • Speed control optimization function (P1960) fault. Fault value = 0: Steady‑state speed not reached within the specified time. Fault value = 1: Reading is illogical. p. 86

What to do

  1. Off2 p. 86

Before you service the product, read the safety instructions in the manual p. 7.

If F0042 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about F0042; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.