Siemens G120C Error 14: Braking controller / Braking Module faulted

Siemens G120C drive · taken from the manufacturer’s manual, pages cited

Fault code14

The braking controller or Braking Module is faulted or overloaded with temperature issues on the Siemens G120C drive. The manual's first action is: “Check the connection/state of the Braking Module. Comply with the permissible number of braking operations and their duration.”

Model
Siemens G120C
Display shows
Braking controller / Braking Module faulted (14)
Type
Fault code
Source
Manual p. 655

What 14 means

Braking controller / Braking Module faulted p. 655

Common causes

  • The internal or external Braking Module is faulted or overloaded (temperature). p. 655

What to do

  1. Check the connection/state of the Braking Module. Comply with the permissible number of braking operations and their duration. p. 655

Before you service the product, read the safety instructions in the manual p. 4.

If 14 is still not resolved

  • contact service / dealer p. 4
    “Warning concept This Manual contains information which you must observe to ensure your own personal safety as well as to avoid material damage.”
  • contact service / dealer p. 12
    “WARNING Danger to life if the safety instructions and residual risks are not observed”

This page summarises what the manufacturer’s manual says about 14; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.