An error was identified in parameterization, configuration, or commissioning procedure, or parameterization does not match device configuration on the Siemens G120C drive. The manual's first action is: “Determine the precise cause of the fault using the commissioning tool. Adapt the parameterization or device configuration.”
- Model
- Siemens G120C
- Display shows
- 18
- Type
- Fault code
- Source
- Manual p. 655
What 18 means
Error in the parameterization/configuration/commissioning procedure p. 655
Common causes
- An error was identified in the parameterization or in a commissioning procedure, or the parameterization does not match the actual device configuration. p. 655
What to do
- Determine the precise cause of the fault using the commissioning tool. Adapt the parameterization or device configuration. p. 655
Before you service the product, read the safety instructions in the manual p. 4.
If 18 is still not resolved
This page summarises what the manufacturer’s manual says about 18; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.