Transmit Slip Indication means a ‘1’ in this bit position indicates an error in the host clock system. The manual's first action is: “If the wander of the transmit‑route clock (normally phase‑locked to a common submultiple of the system clock SCLKX) is excessive, data‑transmission errors will occur. In that case, reset the transmit speech memory to its start position by writing the initial value to the transmit timeslot counter XC1.XTO.”
- Model
- Siemens FALC54
- Display shows
- Transmit Slip Indication (XSLP...)
- Type
- Error code
- Source
- Manual p. 285
What XSLP... means
Transmit Slip Indication p. 285
Common causes
- A ‘1’ in this bit position indicates an error in the host clock system. p. 285
What to do
- If the wander of the transmit‑route clock (normally phase‑locked to a common submultiple of the system clock SCLKX) is excessive, data‑transmission errors will occur. In that case, reset the transmit speech memory to its start position by writing the initial value to the transmit timeslot counter XC1.XTO. p. 285
If XSLP... is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about XSLP...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.