Siemens FALC54 Error LMFA16...: Loss of Multiframe Alignment TS 16

Siemens FALC54 · taken from the manufacturer’s manual, pages cited

Error codeLMFA16...

This code indicates multiframe alignment for timeslot 16 has been lost. The manual's first action is: “If register IPC.SCI is high, this interrupt‑status bit is set with every change of state of FRS1.TS16LFA.”

Model
Siemens FALC54
Display shows
Loss of Multiframe Alignment TS 16 (LMFA16...)
Type
Error code
Source
Manual p. 142

What LMFA16... means

Loss of Multiframe Alignment TS 16 p. 142

Common causes

  • Multiframe alignment for timeslot 16 is lost if two consecutive multiframe patterns are not detected or if all bits are zero in 16 consecutive timeslot 16 samples. p. 142

What to do

  1. If register IPC.SCI is high, this interrupt‑status bit is set with every change of state of FRS1.TS16LFA. p. 142

If LMFA16... is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about LMFA16...; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.