Error codeOLF1
OLF1 means PTC1 probe overheating detected. The manual's first action is: “Check motor load and motor specifications.”
- Model
- Schneider Electric ATV61
- Display shows
- [PTC1 Overheat] (OLF1)
- Type
- Error code
- Source
- Manual p. 243
What OLF1 means
[PTC1 Overheat] p. 243
Common causes
- PTC1 probe overheating detected. p. 243
What to do
- Check motor load and motor specifications. p. 243
- Check motor ventilation. p. 243
- Wait for the motor to cool down before restarting. p. 243
- Check the type and condition of the PTC probe. p. 243
Before you service the product, read the safety instructions in the manual p. 54.
If OLF1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about OLF1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.