Schneider Electric ATV61 · taken from the manufacturer’s manual, pages cited

Error codeOLF1

OLF1 means PTC1 probe overheating detected. The manual's first action is: “Check motor load and motor specifications.”

Model
Schneider Electric ATV61
Display shows
[PTC1 Overheat] (OLF1)
Type
Error code
Source
Manual p. 243

What OLF1 means

[PTC1 Overheat] p. 243

Common causes

  • PTC1 probe overheating detected. p. 243

What to do

  1. Check motor load and motor specifications. p. 243
  2. Check motor ventilation. p. 243
  3. Wait for the motor to cool down before restarting. p. 243
  4. Check the type and condition of the PTC probe. p. 243

Before you service the product, read the safety instructions in the manual p. 54.

If OLF1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about OLF1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.