Schneider Electric ATV61 Error ObF: [Braking Overspeed]

Schneider Electric ATV61 · taken from the manufacturer’s manual, pages cited

Error codeObF

ObF means braking is too aggressive or the driven load has excessive inertia. The manual's first action is: “Increase the deceleration time.”

Model
Schneider Electric ATV61
Display shows
[Braking Overspeed] (ObF)
Type
Error code
Source
Manual p. 242

What ObF means

[Braking Overspeed] p. 242

Common causes

  • Braking is too aggressive or the driven load has excessive inertia. p. 242

What to do

  1. Increase the deceleration time. p. 242
  2. If necessary, install a braking resistor. p. 242
  3. Activate the [Deceleration Time Adaptive] (brA) function on page 132, if this function is compatible with the application. p. 242

Before you service the product, read the safety instructions in the manual p. 54.

If ObF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about ObF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.