Incorrect parameters in the [Settings] (Set‑) and [1.4 Motor Control] (drC‑) menus, excessive mass or load, or mechanical lock. The manual's first action is: “• Check the parameters. • Verify the size of the motor / inverter / load. • Inspect the condition of the mechanical device.”
- Model
- Schneider Electric ATV61
- Display shows
- [Overcurrent] (OCF)
- Type
- Error code
- Source
- Manual p. 240
What OCF means
[Overcurrent] p. 240
Common causes
- Incorrect parameters in the [Settings] (Set‑) and [1.4 Motor Control] (drC‑) menus. • Excessive mass or load. • Mechanical lock. p. 240
What to do
- • Check the parameters. • Verify the size of the motor / inverter / load. • Inspect the condition of the mechanical device. p. 240
Before you service the product, read the safety instructions in the manual p. 54.
If OCF is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.
This page summarises what the manufacturer’s manual says about OCF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.